How to use the radiation dose converter
- Type your number and pick its unit. The unit list spells every unit out in words, so “mSv” shows as “millisievert”. Not sure which unit you have? Open How to use this converter at the top of the converter for a quick guide.
- Choose a tab. Dose converts a total dose. Dose rate & time takes a reading such as 0.3 µSv/h, or counts per minute from a Geiger counter, and works out the total dose over the time you enter.
- Read the result your way. Every unit appears in the results grid (tap one to copy it). Below that, the same dose is shown as bananas, chest X-rays, flights or years of natural background, and placed on a dose ladder. Large doses also show what they would do to the body if received all at once.
Working with alpha particles, protons or neutrons? Open Radiation type & assumptions and set the radiation type. For neutrons, enter the energy: the weighting factor changes a lot with it.
Why are there so many radiation units?
Radiation dose is measured in two systems and at three different stages, which is why the same exposure can be written five different ways.
| What it measures | SI unit | Older US unit | Conversion |
|---|---|---|---|
| Ionization of air by X-rays or gamma rays (exposure) | coulomb per kg (C/kg) | roentgen (R) | 1 R = 2.58 × 10⁻⁴ C/kg |
| Energy absorbed per kilogram (absorbed dose) | gray (Gy) | rad | 1 Gy = 100 rad |
| Absorbed dose weighted for biological harm (equivalent or effective dose) | sievert (Sv) | rem | 1 Sv = 100 rem |
Most of the world uses gray and sievert. The United States still uses rad and rem in many regulations, and older survey meters and textbooks read in roentgen. The converter handles all of them. For a plain-English walkthrough with real examples, read Radiation Units Explained.
Gray vs sievert: what is the difference?
Gray tells you how much energy the radiation left in the body. Sievert tells you how much harm to expect from it. The bridge between them is the radiation weighting factor (wR): sieverts = grays × wR.
| Radiation type | Weighting factor wR (ICRP 103) | 1 Gy equals |
|---|---|---|
| Gamma rays and X-rays | 1 | 1 Sv |
| Beta particles (electrons) | 1 | 1 Sv |
| Protons | 2 | 2 Sv |
| Alpha particles | 20 | 20 Sv |
| Neutrons | ≈ 2.5 to 20.7, by energy | 2.5–20.7 Sv |
That is why “1 Gy = 1 Sv” is only true for gamma rays, X-rays and beta. A gray of alpha radiation inside the body does about twenty times the damage. For neutrons the converter uses the ICRP 103 energy formula: thermal neutrons get about 2.5, and 1 MeV neutrons peak at about 20.7.
One exception matters for large doses. Radiation sickness and other short-term effects follow the absorbed dose in gray, not sieverts. The sievert was built to estimate long-term cancer risk from small doses. That is why the converter’s acute-effects table is labelled in gray.
Why roentgen converters give different answers
Search for “roentgen to sievert” and you will find 1 R = 0.01 Sv, 1 R = 0.00877 Sv and 1 R = 0.0096 Sv, all on different sites. None is a typo. The roentgen measures charge produced in air, so turning it into a dose depends on what material you care about and why:
- Radiation protection (default): 1 R ≈ 1 rad ≈ 1 rem = 10 mSv. This is a deliberate round-number convention used for safety work, and it errs slightly on the cautious side.
- Air kerma: 1 R = 8.77 mGy in air (Cember & Johnson). Use this when matching an instrument calibrated in air kerma.
The converter shows which convention is active and lets you switch it under Radiation type & assumptions. The roentgen is only defined for X-rays and gamma rays, so it shows “n/a” for alpha, beta and neutron radiation.
Converting Geiger counter CPM to µSv/h
A Geiger counter counts pulses, not dose. To turn counts per minute (CPM) into microsieverts per hour you need a factor for your specific tube. The converter includes approximate factors, calibrated on cesium-137 gamma rays, for three common tubes:
| Tube | µSv/h per CPM | 100 CPM ≈ |
|---|---|---|
| SBM-20 | 0.0057 | 0.57 µSv/h |
| GQ GMC-300 / GMC-320 counters | 0.0065 | 0.65 µSv/h |
| LND 7317 (pancake) | 0.003 | 0.30 µSv/h |
Geiger tubes over- or under-respond at other gamma energies and do not measure dose correctly for alpha or beta at all. If your counter came with its own factor, choose “Custom factor” and enter it.
Common radiation dose conversions
| Sieverts | rem | Example at this level |
|---|---|---|
| 0.1 µSv | 0.01 mrem | Eating one banana |
| 35 µSv | 3.5 mrem | One cross-country US flight |
| 0.1 mSv | 10 mrem | Chest X-ray |
| 1 mSv | 100 mrem | Public dose limit from nuclear facilities, per year |
| 6.2 mSv | 620 mrem | Average yearly dose in the US, all sources |
| 7 mSv | 700 mrem | CT scan of the chest |
| 50 mSv | 5 rem | Yearly limit for US radiation workers |
| 100 mSv | 10 rem | Lowest dose with a clear cancer-risk signal in large studies |
| 1 Sv | 100 rem | Radiation sickness begins, if received at once |
| 3–4 Sv | 300–400 rem | LD50/60: about half die within 60 days without treatment |
The last two rows assume gamma or X-ray exposure, where sieverts and grays are equal.
Is my dose dangerous?
For almost every number people type in, no. Doses in microsieverts and single millisieverts sit in the same range as natural background and routine medical imaging. The converter colours its message by range: everyday, medical or occupational, elevated cancer risk, and acute harm. For the full picture, with the evidence behind each threshold, read How Much Radiation Is Dangerous?
Timing matters as much as size. 1,000 mSv received in an hour can cause radiation sickness. The same 1,000 mSv spread over a working lifetime does not. It only raises long-term cancer risk.
Frequently asked questions
How many rem is 1 sievert?
Exactly 100. One sievert (Sv) equals 100 rem, so 1 millisievert (mSv) equals 100 millirem (mrem) and 1 rem equals 10 mSv. The same factor links gray and rad: 1 Gy = 100 rad.
What is the difference between gray and sievert?
Gray (Gy) is absorbed dose: 1 joule of radiation energy deposited in 1 kilogram of tissue. Sievert (Sv) is that dose weighted for how damaging the radiation type is. For gamma rays, X-rays and beta particles the weighting factor is 1, so 1 Gy = 1 Sv. For alpha particles it is 20, so 1 Gy of alpha counts as 20 Sv. For neutrons it is between about 2.5 and 20, depending on energy.
How do I convert roentgen to sievert?
A roentgen (R) measures how much X-ray or gamma radiation ionizes air, not the dose to a person, so there is no single exact factor. Radiation-protection practice treats 1 R as about 1 rem (10 mSv). Physically, 1 R deposits 8.77 mGy in air. The converter lets you pick either convention, and the roentgen only applies to X-rays and gamma rays.
How do I convert Geiger counter CPM to µSv/h?
Multiply the counts per minute by your tube’s conversion factor. For the common SBM-20 tube, calibrated on cesium-137, the factor is about 0.0057 µSv/h per CPM, so 100 CPM is roughly 0.57 µSv/h. Factors differ by tube and by radiation energy, so treat the result as an estimate.
Is 1 mSv a lot of radiation?
No. One millisievert a year is the limit regulators set for the public from nuclear facilities, and it is well below what most people already receive from nature and medicine: the average person in the United States gets about 6.2 mSv a year (NCRP Report 160). A single chest CT scan is around 7 mSv.
What dose of radiation causes radiation sickness?
Radiation sickness starts at about 1 gray (roughly 1,000 mSv of gamma rays) received to the whole body over minutes to hours. Around 3 to 4 Gy, about half of people die within 60 days without intensive medical care (the LD50/60). The same total dose spread over years does not cause radiation sickness.
Is µSv/h the same as µSv?
No. µSv/h is a dose rate — how fast dose builds up. µSv is the dose you end up with. Multiply the rate by the hours of exposure: 0.2 µSv/h for a full year (8,766 hours) adds up to about 1.75 mSv. Use the “Dose rate & time” tab to do this for you.
Does this converter store or send my numbers?
No. Every calculation runs in your browser. Nothing you type is sent to a server or logged. The PDF, Excel and CSV exports are built on your own device.